HLA-7 ปัีมน้ำมันแบบมือโยก ยี่ห้อ Showa

SHOWA HLA7 MANUAL PUMP
Distribution of oil is induced by moving the lever up and down. The HLA7 model has a variable dispensing volume of 1cm3/stroke to 7cm3/stroke, which can be set by adjusting the adjustment nut and stopper positioned next to the lever.
The pump is supplied with a 1L plastic tank and is available with levers facing either direction to suit installation and operational requiriments.
|
Models and Technical Features
Model Type
|
Discharge Volume
|
Average Discharge Pressure (MPa)
|
Discharge Port Size
|
Tank Capacity (L)
|
Effective Tank Capacity (L)
|
HLA7R(L)
|
1 - 7 cc/st
|
0.3 (3Bar)
|
M8 x 1.0
|
1L
|
0.8L
|
* "R" at the end of the reference means the oil outlet at the right side on the pump cover.
* "L" at the end of the reference means the oil outlet at the left side on the pump cover.
HLA7 Hand Pump
- Push lever type manual pump
- Adjustable dispensing volume, ranging from 1c㎥/stroke to 7c㎥/stroke
Distribution of oil is induced by simply moving the lever up and down. The HLA7 model has an adjustable dispensing volume of 1c㎥/stroke to 7c㎥/stroke, which can be set by adjusting the adjustment nut and stopper positioned next to the lever.
The pump is supplied with a 1L plastic tank and is available with levers facing either direction to suit installation and operational requirements.
Form code
Specifications
MODEL CODE |
Discharge Vol.(c㎥/st) |
Max. Discharge Pressure (MPa) |
Discharge Port Size |
Tank Capacity (L) |
Effective Tank Capacity (L) |
HLA7L (R) |
1~7 |
0.3 |
M8×1.0 |
1 |
0.8 |
※The HLA7 pump’s initial discharge volume is set to 7c㎥/st.
※The “R” indicates the pump is to be mounted on the RIGHT in relation to the machine. (viewing from the front) Therefore, the pump’s mounting face is positioned on it’s left when the lever is held straight.
Drawing